Results: 1621
Analysis type: >
Page: 17
| Analysis of substance: | Report limit: |
|---|---|
| Al | |
| Cd, cadmium | |
| Co | |
| Cr, chromium | |
| Cu, copper | |
| Fe | |
| Mn | |
| Ni, nickel | |
| Pb, lead | |
| Zn, zink | |
| U |
Metals (cations) with passive sampling (11 metals) [PSM-1]
Package info
Price: 2.000 NOK / sampleStd. response time: 15 work days
Discount group: 3
Sample type: Passive sampling/water
Analysis type: Elements
Sample amount: 1 DGT (white)
Method: ICP-SFMS SS EN ISO 17294-1, 2 (mod), also EPA-method 200.8 (mod).
Express: No
Accreditation: No
Instruction: Se instruks for prøvetaking med DGT:
INSTRUKS
Remarks: Price for membrane comes in addition
The reporting limit corresponds to the exposure time
Lab: ALS Luleå
| Analysis of substance: | Report limit: |
|---|---|
| Ag | |
| Al | |
| Cd, cadmium | |
| Ce | |
| Co | |
| Cr, chromium | |
| Cu, copper | |
| Dy | |
| Er | |
| Eu | |
| Fe | |
| Gd | |
| Ho | |
| La | |
| Lu | |
| Mn | |
| Nd | |
| Ni, nickel | |
| Pr | |
| Sm | |
| Sr | |
| Tb | |
| Tm | |
| U | |
| Yb | |
| Zn, zink |
Total cations (27 metals), passive sampler analysis [PSM-2]
Package info
Price: 2.655 NOK / sampleStd. response time: 15 work days
Discount group: 3
Sample type: Passive sampling/water
Analysis type: Elements
Container: PS Metal
Method: ICP-SFMS acc ISO 17294-1,2 and EPA 200.8. ICP-AES acc ISO 11885 and EPA 200.7. Hg acc ISO 17852
Express: No
Accreditation: No
Instruction: Se instruks for prøvetaking med DGT:
INSTRUKS
Remarks: Price for membrane comes in addition
The reporting limit corresponds to the exposure time
Lab: ALS Luleå
| Analysis of substance: | Report limit: |
|---|---|
| As, arsenic | |
| phosphorus (total) | |
| Mo | |
| antimony (Sb) | |
| V |
Anions, passive sampler analysis [PSM-3]
Package info
Price: 1.645 NOK / sampleStd. response time: 15 work days
Discount group: 3
Sample type: Passive sampling/water
Analysis type: Other analyses
Sample amount: 1 DGT (pink in the middle)
Method: ICP-SFMS SS EN ISO 17294-1, 2 (mod), also EPA-method 200.8 (mod).
Express: No
Accreditation: No
Instruction: Se instruks for prøvetaking med DGT:
INSTRUKS
Remarks: Price for membrane comes in addition
The reporting limit corresponds to the exposure time
Lab: ALS Luleå
| Analysis of substance: | Report limit: |
|---|---|
| PCB 28 | |
| PCB 52 | |
| PCB 101 | |
| PCB 118 | |
| PCB 138 | |
| PCB 153 | |
| PCB 180 | |
| sum of PCB-7 |
PCB-7 with passive sampling [PSO-2]
Package info
Price: 2.145 NOK / sampleStd. response time: 15 work days
Discount group: 3
Sample type: Passive sampling/water
Analysis type: Organic compounds
Sample amount: 1 SPMD
Container: SPMD (PS Organic)
Method: EPA 1668, mod.
Express: No
Accreditation: No
Instruction: The membrane with contents is extracted with n-hexane before Soxhlet extraction is carried out
Remarks: See instructions for Handling of SPMD (long) and mounting in cages:
INSTRUCTIONS
See instructions for SPMD (small) in a pre-assembled cage:
INSTRUCTIONS
The analysis of the SPMD membrane is accredited. The calculation from ng/SPMD to water concentration is not accredited
Lab: ALS CZ
| Analysis of substance: | Report limit: |
|---|---|
| 2,3,7,8-tetraCDD | |
| 1,2,3,7,8-pentaCDD | |
| 1,2,3,4,7,8-hexaCDD | |
| 1,2,3,6,7,8-hexaCDD | |
| 1,2,3,7,8,9-hexaCDD | |
| 1,2,3,4,6,7,8-heptaCDD | |
| octachlorodibenzodioxin | |
| 2,3,7,8-tetraCDF | |
| 1,2,3,7,8-pentaCDF | |
| 2,3,4,7,8-pentaCDF | |
| 1,2,3,4,7,8-hexaCDF | |
| 1,2,3,6,7,8-hexaCDF | |
| 1,2,3,7,8,9-hexaCDF | |
| 2,3,4,6,7,8-hexaCDF | |
| 1,2,3,4,6,7,8-heptaCDF | |
| 1,2,3,4,7,8,9-heptaCDF | |
| octachlorodibenzofuran |
Dioxins and furans with passive sampling [PSO-4]
Package info
Price: 8.355 NOK / sampleStd. response time: 15 work days
Discount group: 3
Sample type: Passive sampling/water
Analysis type: Organic compounds
Sample amount: 1 SPMD
Container: SPMD (PS Organic)
Accreditation: No
Remarks: The analysis of the SPMD membrane is accredited. The calculation from ng/SPMD to water concentration is not accredited
See instructions for Handling of SPMD (long) and mounting in cages:
INSTRUCTIONS
See instructions for SPMD (small) in a pre-assembled cage:
INSTRUCTIONS
Lab: ALS CZ
| Analysis of substance: | Report limit: |
|---|---|
| actinolite 1 | påvist/ikke påvist |
| amosite 1 | påvist/ikke påvist |
| anthophyllite 1 | påvist/ikke påvist |
| chrysotile 1 | påvist/ikke påvist |
| crocidolite 1 | påvist/ikke påvist |
| tremolite 1 | påvist/ikke påvist |
Asbestos, qualitative in dust samples [A-2b]
Package info
Price: 1.460 NOK / sampleStd. response time: 5 work days
Fastest response time: Sameday
Discount group: 1
Sample type: Construction material etc.
Analysis type: Particles/asbestos
Sample amount: 10 cm
Container: ALS Sampling tape + 2x zip bags(170x 230 mm)
Method: ISO 16000-27 (Preparation acc. to ISO 22262-1)
Express: Yes, Fastest delivery sameday ekspress: 300% addition, 09.00: 200%, 1d: 100%, 2d: 75%, 3d: 50%, 4d: 30%, 5d: 20%
Accreditation: Yes
Instruction: Sampled on tape. Stick together after sampling
Remarks: Transparent tape needed. Use ALS sampling tape
Lab: ALS Oslo
1 Detection limit is 0,1 weight%
| Analysis of substance: | Report limit: |
|---|---|
| fibers 1 | 0.01 fibre/cm3 |
Asbestos in air - Limits according to The Norwegian Labour Inspection Authority [A-2a-SANERING]
Package info
Price: 2.220 NOK / sampleStd. response time: 5 work days
Fastest response time: Sameday
Discount group: 1
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 600 L
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: ISO 14966
Express: Yes, Fastest delivery sameday ekspress: 300% addition, 09.00: 200%, 1d: 100%, 2d: 75%, 3d: 50%, 4d: 30%, 5d: 20%
Accreditation: Yes
Remarks: Se instruks for prøvetaking av abest i luft:
INSTRUKS
Notify which fiber types are expected in the sample. Regarding asbestos, the asbestos type is identified. The reported value is a sum of all fibres in the sample
Price is for analysis. Additional price for filter.
Lab: ALS Oslo
1 The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The method is accredited for the filter size Polycarbonate plates for SEM, 25 mm. Other filter sizes give unaccredited results.
| Analysis of substance: | Report limit: |
|---|---|
| Spores | 7 fibres/mm^2 |
Mold- and spore content on filter [A-3g]
Package info
Price: 1.895 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Mold and dry rot fungus
Sample amount: Recommended volume 500-1500 liters
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: SEM
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The analysis can only be used to find out if there are spores in the air, not to specify the spores.
Lab: ALS Stockholm
| Analysis of substance: | Report limit: |
|---|---|
Particle determination, quantitative, on filter samples (concentration, size and type) [A-4a]
Package info
Price: 4.410 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: Recommended volume 500-1500 liters
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: SEM
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The analysis identifies what type of particles are present and at which size. The amount >1µm and <1µm are being calculated
Lab: ALS Stockholm
| Analysis of substance: | Report limit: |
|---|---|
Particle determination, qualitative, in material samples or on tape (identification of different particle types) [A-4b]
Package info
Price: 3.225 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 10 cm
Container: ALS Sampling tape + 2x zip bags(170x 230 mm)
Method: In-house method, SEM
Express: Yes
Accreditation: No
Remarks: The analysis is qualitative and is used to identify what particle types are presenr in dust (or material). The particles are divided into groups depending on their composition. This can be used to look for certain particles or find out the origin.
Lab: ALS Stockholm
| Analysis of substance: | Report limit: |
|---|---|
| <1 µm | % |
| 1-2 µm | % |
| 2-5 µm | % |
| 5-10 µm | % |
| 10-20 µm | % |
| >20 µm | % |
Particle size distribution [A-4c]
Package info
Price: 3.320 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The analysis is for particles in size generally being between >0.1 och <100 µm. For particle sizes outside this area other analysis are needed. The results are presented in table both in amount% and weight%
See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
Lab: ALS Stockholm
| Analysis of substance: | Report limit: |
|---|---|
| Volume (non accredited) | m3 |
| Dust weight | 0.1 mg |
| Dust weight, calculated | mg/m3 |
Total dust (total dust, respirable or inhalable), excl. filter [A-4d]
Package info
Price: 460 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 1 pc.
Container: Mixed cellulose 0.8 µm (total dust filter), 25 alt. 37 mm, weight [A-4d]
Express: No
Accreditation: No
Remarks: Lab: ALS Stockholm
| Analysis of substance: | Report limit: |
|---|---|
| Quartz | 5 µg total |
Quartz in respirable dust on filter samples (FTIR) [A-5a]
Package info
Price: 830 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: In-house method, based on NIOSH 7602
Express: No
Accreditation: Yes
Remarks: Lab: ALS CZ
| Analysis of substance: | Report limit: |
|---|---|
Semi-quantitative SEM/EDS analysis [A-4e]
Package info
Price: 1.595 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: In-house method, SEM
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The analysis is used to see what elements a material is constituted of. Elements with atom number lower than 6 can not be identified
Lab: ALS Stockholm
| Analysis of substance: | Report limit: |
|---|---|
| Inhalable dust | µg/m3 |
| Quartz | µg/m3 |
| Cristobalite | µg/m3 |
| Tridymite | µg/m3 |
| Total silica | µg/sample |
Respirable Crystalline Silica [A-5C]
Package info
Price: 4.040 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 400 liter
Container: PVC-filter 37 mm MW
Method: Respirable Dust by NIOSH 0600 mod., and Silica by NIOSH 7500 mod.
Express: No
Accreditation: No
Remarks: The analysis reported in µg/sample is accredited, while the calculation to µg/m3 is not accredited
Determination of quartz, tridymite and cristobalite as total silica and total respirable dust by XRF
Lab: ALS Salt Lake City
| Analysis of substance: | Report limit: |
|---|---|
| Hg, mercury | 0.02 µg total |
Mercury (Hg) on adsorption tubes [A-6c]
Package info
Price: 965 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Elements
Accreditation: Yes
Instruction: Sampling volume: 2 liters/min for 2 hours
Remarks: Lab: ALS Luleå
| Analysis of substance: | Report limit: |
|---|---|
| Al | 0.1 µg total |
| As, arsenic | 0.005 µg total |
| Ba | 0.01 µg total |
| Be | 0.0005 µg total |
| Cd, cadmium | 0.0005 µg total |
| Cr, chromium | 0.01 µg total |
| Mo | 0.0005 µg total |
| Ni, nickel | 0.005 µg total |
| V | 0.001 µg total |
| Zn, zink | 0.5 µg total |
Metals in total dust on filter [A-6t]
Package info
Price: 1.895 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: ISO 17294-1,2 (mod.) og EPA 200.8 (mod.)
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: Suitable filter: Mixed cellulose membrane filter in mointor. Size 25mm or 37mm
Price for individual elements: 750 NOK, then 250 NOK per element.
Lab: ALS Luleå
| Analysis of substance: | Report limit: |
|---|---|
| Co | 0.0005 µg total |
| K | 50 µg total |
| Li | 0.01 µg total |
| Mn | 0.005 µg total |
| Na (sodium) | 5 µg total |
| Pb, lead | 0.001 µg total |
| Sn | 0.005 µg total |
Metals in inhalable dust [A-6i]
Package info
Price: 1.230 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: ISO 17294-1,2 (mod.) og EPA 200.8 (mod.)
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: Lab: ALS Luleå
| Analysis of substance: | Report limit: |
|---|---|
| Al | 0.1 µg total |
| Cd, cadmium | 0.0005 µg total |
| Ca | 2 µg total |
| Cu, copper | 0.02 µg total |
| Fe | 0.2 µg total |
| Mn | 0.005 µg total |
| Mo | 0.0005 µg total |
| Pb, lead | 0.001 µg total |
| V | 0.001 µg total |
| Zn, zink | 0.5 µg total |
Metals in respirable dust [A-6r]
Package info
Price: 1.230 NOK / sampleStd. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: ISO 17294-1,2 (mod.) og EPA 200.8 (mod.)
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: Suitable filter. Filter for foravskiller, 37mm or 25mm, in monitor
Lab: ALS Luleå
| Analysis of substance: | Report limit: |
|---|---|
| Cr(VI), Cr6+ | 0.25 µg total |
Cr(VI) on filter [Cr6-F]
Package info
Price: 1.000 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Elements
Method: EPA 425, ISO 16740
Express: No
Accreditation: Yes
Remarks: Se instruks for prøvetaking av inhalerbart støv for Cr6:
INSTRUKS
Lab: ALS CZ
| Analysis of substance: | Report limit: |
|---|---|
| dichloromethane | 0.2 µg total |
| 1,1-dichloroethane | 0.2 µg total |
| 1,2-dichloroethane | 0.2 µg total |
| 1,1-dichloroethene | 0.2 µg total |
| cis/trans-1,2-dichloroethene | 0.2 µg total |
| 1,2-dichloropropane | 0.2 µg total |
| trichloromethane | 0.2 µg total |
| tetrachloromethane | 0.2 µg total |
| 1,1,1-trichloroethane | 0.2 µg total |
| 1,1,2-trichloroethane | 0.2 µg total |
Chlorinated aliphatics in adsorption tubes [Menu A1]
Package info
Price: 2.335 NOK / sampleStd. response time: 10 work days
Fastest response time: 5 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Method: VDI 3865-3 (CS2-Ekstrakt, GC-MSD): 1998-06
Express: Yes, Fastest delivery 5 workdays, 100% addition.
Accreditation: Yes
Remarks: The analysis uses coal tubes and active sampling
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: GBA
| Analysis of substance: | Report limit: |
|---|---|
| benzene | 0.2 µg total |
| toluene | 0.2 µg total |
| ethylbenzene | 0.2 µg total |
| o-xylen | 0.2 µg total |
| m/p-xylene | 0.2 µg total |
Aromatics in adsorption tubes [Menu A3]
Package info
Price: 2.965 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 coal tube
Method: in-house method, NIOSH.
Express: No
Accreditation: Yes
Instruction: Instruction in Norwegian for sampling air with pump:
INSTRUKS
Remarks: Sample with SKC 226-01, flow 200 ml/min
See instructions for sampling with SKC AirChek Touch:
INSTRUCTIONS
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ
| Analysis of substance: | Report limit: |
|---|---|
| n-hexane | 0.5 µg total |
| n-heptane | 0.2 µg total |
| n-octane | 0.2 µg total |
| n-nonane | 0.2 µg total |
| n-decane | 0.2 µg total |
| n-undecane | 0.2 µg total |
| n-dodecane | 0.2 µg total |
| fraction >C6-C7 | 2.0 µg total |
| fraction >C7-C8 | 2.0 µg total |
| fraction >C8-C9 | 2.0 µg total |
| fraction >C9-C10 | 2.0 µg total |
| fraction >C10-C11 | 2.0 µg total |
| fraction >C11-C12 | 2.0 µg total |
| fraction >C12-C13 | 2.0 µg total |
Aliphatics in adsorption tubes [Menu A4]
Package info
Price: 2.095 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 coal tube
Method: In-house method, CS2-extract, GC-MSD
Express: No
Accreditation: Yes
Instruction: Instruction in Norwegian for sampling air with pump:
INSTRUKS
Remarks: Måleusikkerhet (MU) 15 %
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ
| Analysis of substance: | Report limit: |
|---|---|
| ethanol | 0.2-9 µg total |
| 1-propanol | 0.2-9 µg total |
| 2-propanol (Isopropanol) | 0.2-9 µg total |
| 1-butanol | 0.2-9 µg total |
| 2-butanol | 0.2-9 µg total |
| ethylacetate | 0.2-9 µg total |
| vinyl acetate | 0.2-9 µg total |
| n-butyl acetate | 0.2-9 µg total |
| isobutyl acetate | 0.2-9 µg total |
| acetone | 0.2-9 µg total |
| methylethyl ketone (MEK) | 0.2-9 µg total |
| 4-methyl-2-pentanone (MIBK) | 0.2-9 µg total |
| cyclohexanone | 0.2-9 µg total |
| benzene | 0.2-9 µg total |
| toluene | 0.2-9 µg total |
| ethylbenzene | 0.2-9 µg total |
| sum of xylenes | |
| styrene | 0.2-9 µg total |
Volatile organic compounds in adsorbtion tubes [Menu A5]
Package info
Price: 1.585 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Method: VDI 3865-3 (CS2-Ekstrakt, GC-MSD): 1998-06 and CS2-Ekstrakt, GC-MSD
Express: No
Accreditation: Yes
Remarks: See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: GBA
| Analysis of substance: | Report limit: |
|---|---|
| Aromatics >C8-C10 | 5000 µg/m3 |
| aliphatics >C6-C8 | 5000 µg/m3 |
| aliphatics >C8-C10 | 5000 µg/m3 |
| aliphatics >C10-C12 | 5000 µg/m3 |
| fraction >C6-C7 | 1000 µg/m3 |
| fraction >C7-C8 | 1000 µg/m3 |
| fraction >C8-C9 | 1000 µg/m3 |
| fraction >C9-C10 | 1000 µg/m3 |
| fraction >C10-C11 | 1000 µg/m3 |
| fraction >C11-C12 | 1000 µg/m3 |
| fraction >C12-C13 | 1000 µg/m3 |
| n-pentane | 500 µg/m3 |
| n-hexane | 200 µg/m3 |
| n-heptane | 100 µg/m3 |
| n-octane | 100 µg/m3 |
| n-nonane | 100 µg/m3 |
| n-decane | 100 µg/m3 |
| n-undecane | 100 µg/m3 |
| n-dodecane | 100 µg/m3 |
| n-tetradecane | 100 µg/m3 |
| n-tridecane | 100 µg/m3 |
| n-hexadecane | 100 µg/m3 |
| 1,2,3-trimethylbenzene | 100 µg/m3 |
| 1,2,4-trimethylbenzene | 100 µg/m3 |
| 1,3,5-trimethylbenzene (mesitylene) | 100 µg/m3 |
| 1,2,4,5-tetramethylbenzene | 100 µg/m3 |
| 2-ethyltoluene | 100 µg/m3 |
| 3-ethyltoluene | 100 µg/m3 |
| 4-ethyltoluene | 100 µg/m3 |
| 4-phenylcyclohexene | 100 µg/m3 |
| p-isopropyl toluene | 100 µg/m3 |
| sec-butylbenzene | 100 µg/m3 |
| styrene | 100 µg/m3 |
| tert-butylbenzene | 100 µg/m3 |
| n-butylbenzene | 100 µg/m3 |
| n-propylbenzene | 100 µg/m3 |
| benzene | 50 µg/m3 |
| toluene | 50 µg/m3 |
| ethylbenzene | 50 µg/m3 |
| o-xylen | 50 µg/m3 |
| m/p-xylene | 50 µg/m3 |
| 3-carene | 100 µg/m3 |
| alpha-pinene | 100 µg/m3 |
| beta-pinene | 100 µg/m3 |
| alfa-terpinene | 100 µg/m3 |
| limonene | 200 µg/m3 |
| 1,1,1,2-tetrachloroethane | 100 µg/m3 |
| 1,1,1-trichloroethane | 100 µg/m3 |
| 1,1,2,2-tetrachloroethane | 100 µg/m3 |
| 1,1,2-trichloroethane | 100 µg/m3 |
| 1,1-dichloroethane | 100 µg/m3 |
| 1,1-dichloro-1-propene | 100 µg/m3 |
| 1,2,3-trichloropropane | 100 µg/m3 |
| 1,1-dichloroethene | 100 µg/m3 |
| 1,2-dibromo-3-chloropropane | 100 µg/m3 |
| 1,2-dibromoethane | 100 µg/m3 |
| 1,2-dichloroethane | 100 µg/m3 |
| 1,2-dichlorobenzene | 100 µg/m3 |
| 1,2-dichloropropane | 100 µg/m3 |
| 1,3-dichlorobenzene | 100 µg/m3 |
| 1,3-dichloropropane | 100 µg/m3 |
| 1,4-dichlorobenzene | 100 µg/m3 |
| 1,2,3-trichlorobenzene | 100 µg/m3 |
| 1,2,4-trichlorobenzene | 100 µg/m3 |
| 2,2-dichloropropane | 100 µg/m3 |
| 2-chlorotoluene | 100 µg/m3 |
| 4-chlorotoluene | 100 µg/m3 |
| bromobenzene | 100 µg/m3 |
| tribromomethane (bromoform) | 100 µg/m3 |
| bromochloromethane | 100 µg/m3 |
| bromodichloromethane | 100 µg/m3 |
| bromomethane | 100 µg/m3 |
| chloroethane | 100 µg/m3 |
| chloromethane | 100 µg/m3 |
| cis-1,2-dichloroethene | 100 µg/m3 |
| cis-1,3-dichloro-1-propene | 100 µg/m3 |
| dibromochloromethane | 100 µg/m3 |
| dibromomethane | 100 µg/m3 |
| dichlorodifluoromethane | 100 µg/m3 |
| dichloromethane | 100 µg/m3 |
| hexachlorobutadiene (HCB) | 100 µg/m3 |
| chlorobenzene | 100 µg/m3 |
| tetrachloroethene | 100 µg/m3 |
| tetrachloromethane | 100 µg/m3 |
| trans-1,2-dichloroethene | 100 µg/m3 |
| trans-1,3-dichloro-1-propene | 100 µg/m3 |
| trichloroethene | 100 µg/m3 |
| trichlorofluoromethane | 100 µg/m3 |
| trichloromethane | 100 µg/m3 |
| vinylchloride | µg/m3 |
| 2-Butanone | 100 µg/m3 |
| hexanal | 100 µg/m3 |
| acetone | 100 µg/m3 |
| cyclohexanone | 100 µg/m3 |
| 4-methyl-2-pentanone (MIBK) | 100 µg/m3 |
| 1,4-dichlorobenzene | 100 µg/m3 |
| 2-methylhexane | 100 µg/m3 |
| 4-phenylcyclohexene | 100 µg/m3 |
| cyclohexane | 100 µg/m3 |
| isooctane | 100 µg/m3 |
| methyl-tert-butylether (MTBE) | 100 µg/m3 |
| ETBE | 100 µg/m3 |
| 2-ethyl-1-hexanol | 100 µg/m3 |
| 2-methyl-1-butanol | 100 µg/m3 |
| isobutanol | 100 µg/m3 |
| 1-propanol | 100 µg/m3 |
| 1-butanol | 100 µg/m3 |
| 2-butanol | 200 µg/m3 |
| 2-propanol (Isopropanol) | 100 µg/m3 |
| ethanol | 1000 µg/m3 |
| isobutyl acetate | 200 µg/m3 |
| n-butyl acetate | 200 µg/m3 |
| tert-butyl acetate | 100 µg/m3 |
| ethylacetate | 200 µg/m3 |
| vinyl acetate | 100 µg/m3 |
| naphthalene | 1000 µg/m3 |
Aromatics and halogenated volatile compounds (VOC) in air samples, large package (96 compounds) [Menu A7]
Package info
Price: 4.410 NOK / sampleStd. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 coal tube
Method: NIOSH
Express: No
Accreditation: Yes
Instruction: Instruction in Norwegian for sampling air with pump:
INSTRUKS
Remarks: See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ