Page: 18
Analysis of substance: Report limit:
Spores 7 fibres/mm^2

Mold- and spore content on filter [A-3g]

Package info

Price: 1.895 NOK / sample
Std. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Mold and dry rot fungus
Sample amount: Recommended volume 500-1500 liters
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: SEM
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The analysis can only be used to find out if there are spores in the air, not to specify the spores.
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Stockholm
Analysis of substance: Report limit:

Particle determination, quantitative, on filter samples (concentration, size and type) [A-4a]

Package info

Price: 4.410 NOK / sample
Std. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: Recommended volume 500-1500 liters
Container: Polycarbonate filter in monitor for SEM, 25 mm
Method: SEM
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The detection limit changes with the sample volume. Filters with larger diameter has a higher detection limit and are used only when there is much dust in the air
The analysis identifies what type of particles are present and at which size. The amount >1µm and <1µm are being calculated
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Stockholm
Analysis of substance: Report limit:

Particle determination, qualitative, in material samples or on tape (identification of different particle types) [A-4b]

Package info

Price: 3.225 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 5-10 cm
Container: ALS Sampling tape + 2x zip bags(170x 230 mm)
Method: In-house method, SEM
Express: Yes
Accreditation: No
Remarks: The analysis is qualitative and is used to identify what particle types are presenr in dust (or material). The particles are divided into groups depending on their composition. This can be used to look for certain particles or find out the origin.
Lab: ALS Stockholm
Analysis of substance: Report limit:
<1 µm %
1-2 µm %
2-5 µm %
5-10 µm %
10-20 µm %
>20 µm %

Particle size distribution [A-4c]

Package info

Price: 3.320 NOK / sample
Std. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The analysis is for particles in size generally being between >0.1 och <100 µm. For particle sizes outside this area other analysis are needed. The results are presented in table both in amount% and weight%
See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Stockholm
Analysis of substance: Report limit:
Volume (non accredited) m3
Dust weight 0.1 mg
Dust weight, calculated mg/m3

Total dust (total dust, respirable or inhalable), excl. filter [A-4d]

Package info

Price: 460 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 1 pc.
Container: Mixed cellulose 0.8 µm (total dust filter), 25 alt. 37 mm, weight [A-4d]
Express: No
Accreditation: No
Remarks: Lab: ALS Stockholm
Analysis of substance: Report limit:
Quartz 5 µg total

Quartz in respirable dust on filter samples (FTIR) [A-5a]

Package info

Price: 830 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: In-house method, based on NIOSH 7602
Express: No
Accreditation: Yes
Remarks: See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: Report limit:

Semi-quantitative SEM/EDS analysis [A-4e]

Package info

Price: 1.595 NOK / sample
Std. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: In-house method, SEM
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: The analysis is used to see what elements a material is constituted of. Elements with atom number lower than 6 can not be identified
Eksempel på hvordan en rapport kan se ut klikk her
Lab: ALS Stockholm
Analysis of substance: Report limit:
Inhalable dust µg/m3
Quartz µg/m3
Cristobalite µg/m3
Tridymite µg/m3
Total silica µg/sample

Respirable Crystalline Silica [A-5C]

Package info

Price: 4.040 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Sample amount: 400 liter
Container: PVC-filter 37 mm MW
Method: Respirable Dust by NIOSH 0600 mod., and Silica by NIOSH 7500 mod.
Express: No
Accreditation: No
Remarks: The analysis reported in µg/sample is accredited, while the calculation to µg/m3 is not accredited
Determination of quartz, tridymite and cristobalite as total silica and total respirable dust by XRF
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Salt Lake City
Analysis of substance: Report limit:
Hg, mercury 0.02 µg total

Mercury (Hg) on adsorption tubes [A-6c]

Package info

Price: 965 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Elements
Accreditation: Yes
Instruction: Sampling volume: 2 liters/min for 2 hours
Remarks: See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Luleå
Analysis of substance: Report limit:
Al 0.1 µg total
As, arsenic 0.005 µg total
Ba 0.01 µg total
Be 0.0005 µg total
Cd, cadmium 0.0005 µg total
Cr, chromium 0.01 µg total
Mo 0.0005 µg total
Ni, nickel 0.005 µg total
V 0.001 µg total
Zn, zink 0.5 µg total

Metals in total dust on filter [A-6t]

Package info

Price: 1.895 NOK / sample
Std. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: ISO 17294-1,2 (mod.) og EPA 200.8 (mod.)
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: Suitable filter: Mixed cellulose membrane filter in mointor. Size 25mm or 37mm
Price for individual elements: 750 NOK, then 250 NOK per element.
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Luleå
Analysis of substance: Report limit:
Co 0.0005 µg total
K 50 µg total
Li 0.01 µg total
Mn 0.005 µg total
Na (sodium) 5 µg total
Pb, lead 0.001 µg total
Sn 0.005 µg total

Metals in inhalable dust [A-6i]

Package info

Price: 1.230 NOK / sample
Std. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: ISO 17294-1,2 (mod.) og EPA 200.8 (mod.)
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Luleå
Analysis of substance: Report limit:
Al 0.1 µg total
Cd, cadmium 0.0005 µg total
Ca 2 µg total
Cu, copper 0.02 µg total
Fe 0.2 µg total
Mn 0.005 µg total
Mo 0.0005 µg total
Pb, lead 0.001 µg total
V 0.001 µg total
Zn, zink 0.5 µg total

Metals in respirable dust [A-6r]

Package info

Price: 1.230 NOK / sample
Std. response time: 10 work days
Fastest response time: 1 work day
Discount group: 5
Sample type: Air/Work environment
Analysis type: Particles/asbestos
Method: ISO 17294-1,2 (mod.) og EPA 200.8 (mod.)
Express: Yes, Fastest delivery 1 workday, 100% addition. 2 days: 75%, 3 days: 50%
Accreditation: No
Remarks: Suitable filter. Filter for foravskiller, 37mm or 25mm, in monitor
See instructions for sampling with glass fiber filter and XAD-2 tube:
INSTRUCTIONS
Lab: ALS Luleå
Analysis of substance: Report limit:
Cr(VI), Cr6+ 0.25 µg total

Cr(VI) on filter [Cr6-F]

Package info

Price: 1.000 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Elements
Method: EPA 425, ISO 16740
Express: No
Accreditation: Yes
Remarks: Se instruks for prøvetaking av inhalerbart støv for Cr6:
INSTRUKS
Lab: ALS CZ
Analysis of substance: Report limit:
dichloromethane 0.2 µg total
1,1-dichloroethane 0.2 µg total
1,2-dichloroethane 0.2 µg total
1,1-dichloroethene 0.2 µg total
cis/trans-1,2-dichloroethene 0.2 µg total
1,2-dichloropropane 0.2 µg total
trichloromethane 0.2 µg total
tetrachloromethane 0.2 µg total
1,1,1-trichloroethane 0.2 µg total
1,1,2-trichloroethane 0.2 µg total

Chlorinated aliphatics in adsorption tubes [Menu A1]

Package info

Price: 2.335 NOK / sample
Std. response time: 10 work days
Fastest response time: 5 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Method: VDI 3865-3 (CS2-Ekstrakt, GC-MSD): 1998-06
Express: Yes, Fastest delivery 5 workdays, 100% addition.
Accreditation: Yes
Remarks: The analysis uses coal tubes and active sampling
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: GBA
Analysis of substance: Report limit:
benzene 0.2 µg total
toluene 0.2 µg total
ethylbenzene 0.2 µg total
o-xylen 0.2 µg total
m/p-xylene 0.2 µg total

Aromatics in adsorption tubes [Menu A3]

Package info

Price: 2.965 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 coal tube
Method: in-house method, NIOSH.
Express: No
Accreditation: Yes
Instruction: Instruction in Norwegian for sampling air with pump:
INSTRUKS
Remarks: Sample with SKC 226-01, flow 200 ml/min
See instructions for sampling with SKC AirChek Touch:
INSTRUCTIONS
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: Report limit:
n-hexane 0.5 µg total
n-heptane 0.2 µg total
n-octane 0.2 µg total
n-nonane 0.2 µg total
n-decane 0.2 µg total
n-undecane 0.2 µg total
n-dodecane 0.2 µg total
fraction >C6-C7 2.0 µg total
fraction >C7-C8 2.0 µg total
fraction >C8-C9 2.0 µg total
fraction >C9-C10 2.0 µg total
fraction >C10-C11 2.0 µg total
fraction >C11-C12 2.0 µg total
fraction >C12-C13 2.0 µg total

Aliphatics in adsorption tubes [Menu A4]

Package info

Price: 2.095 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 coal tube
Method: In-house method, CS2-extract, GC-MSD
Express: No
Accreditation: Yes
Instruction: Instruction in Norwegian for sampling air with pump:
INSTRUKS
Remarks: Måleusikkerhet (MU) 15 %
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: Report limit:
ethanol 0.2-9 µg total
1-propanol 0.2-9 µg total
2-propanol (Isopropanol) 0.2-9 µg total
1-butanol 0.2-9 µg total
2-butanol 0.2-9 µg total
ethylacetate 0.2-9 µg total
vinyl acetate 0.2-9 µg total
n-butyl acetate 0.2-9 µg total
isobutyl acetate 0.2-9 µg total
acetone 0.2-9 µg total
methylethyl ketone (MEK) 0.2-9 µg total
4-methyl-2-pentanone (MIBK) 0.2-9 µg total
cyclohexanone 0.2-9 µg total
benzene 0.2-9 µg total
toluene 0.2-9 µg total
ethylbenzene 0.2-9 µg total
sum of xylenes
styrene 0.2-9 µg total

Volatile organic compounds in adsorbtion tubes [Menu A5]

Package info

Price: 1.585 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Method: VDI 3865-3 (CS2-Ekstrakt, GC-MSD): 1998-06 and CS2-Ekstrakt, GC-MSD
Express: No
Accreditation: Yes
Remarks: See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: GBA
Analysis of substance: Report limit:
Aromatics >C8-C10 5000 µg/m3
aliphatics >C6-C8 5000 µg/m3
aliphatics >C8-C10 5000 µg/m3
aliphatics >C10-C12 5000 µg/m3
fraction >C6-C7 1000 µg/m3
fraction >C7-C8 1000 µg/m3
fraction >C8-C9 1000 µg/m3
fraction >C9-C10 1000 µg/m3
fraction >C10-C11 1000 µg/m3
fraction >C11-C12 1000 µg/m3
fraction >C12-C13 1000 µg/m3
n-pentane 500 µg/m3
n-hexane 200 µg/m3
n-heptane 100 µg/m3
n-octane 100 µg/m3
n-nonane 100 µg/m3
n-decane 100 µg/m3
n-undecane 100 µg/m3
n-dodecane 100 µg/m3
n-tetradecane 100 µg/m3
n-tridecane 100 µg/m3
n-hexadecane 100 µg/m3
1,2,3-trimethylbenzene 100 µg/m3
1,2,4-trimethylbenzene 100 µg/m3
1,3,5-trimethylbenzene (mesitylene) 100 µg/m3
1,2,4,5-tetramethylbenzene 100 µg/m3
2-ethyltoluene 100 µg/m3
3-ethyltoluene 100 µg/m3
4-ethyltoluene 100 µg/m3
4-phenylcyclohexene 100 µg/m3
p-isopropyl toluene 100 µg/m3
sec-butylbenzene 100 µg/m3
styrene 100 µg/m3
tert-butylbenzene 100 µg/m3
n-butylbenzene 100 µg/m3
n-propylbenzene 100 µg/m3
benzene 50 µg/m3
toluene 50 µg/m3
ethylbenzene 50 µg/m3
o-xylen 50 µg/m3
m/p-xylene 50 µg/m3
3-carene 100 µg/m3
alpha-pinene 100 µg/m3
beta-pinene 100 µg/m3
alfa-terpinene 100 µg/m3
limonene 200 µg/m3
1,1,1,2-tetrachloroethane 100 µg/m3
1,1,1-trichloroethane 100 µg/m3
1,1,2,2-tetrachloroethane 100 µg/m3
1,1,2-trichloroethane 100 µg/m3
1,1-dichloroethane 100 µg/m3
1,1-dichloro-1-propene 100 µg/m3
1,2,3-trichloropropane 100 µg/m3
1,1-dichloroethene 100 µg/m3
1,2-dibromo-3-chloropropane 100 µg/m3
1,2-dibromoethane 100 µg/m3
1,2-dichloroethane 100 µg/m3
1,2-dichlorobenzene 100 µg/m3
1,2-dichloropropane 100 µg/m3
1,3-dichlorobenzene 100 µg/m3
1,3-dichloropropane 100 µg/m3
1,4-dichlorobenzene 100 µg/m3
1,2,3-trichlorobenzene 100 µg/m3
1,2,4-trichlorobenzene 100 µg/m3
2,2-dichloropropane 100 µg/m3
2-chlorotoluene 100 µg/m3
4-chlorotoluene 100 µg/m3
bromobenzene 100 µg/m3
tribromomethane (bromoform) 100 µg/m3
bromochloromethane 100 µg/m3
bromodichloromethane 100 µg/m3
bromomethane 100 µg/m3
chloroethane 100 µg/m3
chloromethane 100 µg/m3
cis-1,2-dichloroethene 100 µg/m3
cis-1,3-dichloro-1-propene 100 µg/m3
dibromochloromethane 100 µg/m3
dibromomethane 100 µg/m3
dichlorodifluoromethane 100 µg/m3
dichloromethane 100 µg/m3
hexachlorobutadiene (HCB) 100 µg/m3
chlorobenzene 100 µg/m3
tetrachloroethene 100 µg/m3
tetrachloromethane 100 µg/m3
trans-1,2-dichloroethene 100 µg/m3
trans-1,3-dichloro-1-propene 100 µg/m3
trichloroethene 100 µg/m3
trichlorofluoromethane 100 µg/m3
trichloromethane 100 µg/m3
vinylchloride µg/m3
2-Butanone 100 µg/m3
hexanal 100 µg/m3
acetone 100 µg/m3
cyclohexanone 100 µg/m3
4-methyl-2-pentanone (MIBK) 100 µg/m3
1,4-dichlorobenzene 100 µg/m3
2-methylhexane 100 µg/m3
4-phenylcyclohexene 100 µg/m3
cyclohexane 100 µg/m3
isooctane 100 µg/m3
methyl-tert-butylether (MTBE) 100 µg/m3
ETBE 100 µg/m3
2-ethyl-1-hexanol 100 µg/m3
2-methyl-1-butanol 100 µg/m3
isobutanol 100 µg/m3
1-propanol 100 µg/m3
1-butanol 100 µg/m3
2-butanol 200 µg/m3
2-propanol (Isopropanol) 100 µg/m3
ethanol 1000 µg/m3
isobutyl acetate 200 µg/m3
n-butyl acetate 200 µg/m3
tert-butyl acetate 100 µg/m3
ethylacetate 200 µg/m3
vinyl acetate 100 µg/m3
naphthalene 1000 µg/m3

Aromatics and halogenated volatile compounds (VOC) in air samples, large package (96 compounds) [Menu A7]

Package info

Price: 4.410 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 coal tube
Method: NIOSH
Express: No
Accreditation: Yes
Instruction: Instruction in Norwegian for sampling air with pump:
INSTRUKS
Remarks: See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: Report limit:
1,1,1-trichloroethane µg/m3
1,2,4-trimethylbenzene µg/m3
1,4-dichlorobenzene µg/m3
2-ethyl-1-hexanol µg/m3
2-propanol (Isopropanol) µg/m3
alpha-pinene µg/m3
benzene µg/m3
cyclohexane µg/m3
ethanol µg/m3
ethylacetate µg/m3
ethylbenzene µg/m3
isobutanol µg/m3
isobutyl acetate µg/m3
isooctane µg/m3
isopropylbenzene µg/m3
limonene µg/m3
m/p-xylene µg/m3
Methyl iso-butyl ketone µg/m3
methylcyclohexane µg/m3
methylcyclopentane µg/m3
naphthalene µg/m3
n-butanol µg/m3
n-butyl acetate µg/m3
n-decane µg/m3
n-dodecane µg/m3
n-heptane µg/m3
n-hexane µg/m3
n-nonane µg/m3
n-octane µg/m3
n-propylbenzene µg/m3
n-undecane µg/m3
o-xylen µg/m3
sum of xylenes µg/m3
styrene µg/m3
tetrachloroethene µg/m3
toluene µg/m3
trichloroethene µg/m3

Meny A7 - Aromatics and halogenated volatile compounds (VOC) radiello

Package info

Price: 4.410 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 coal tube
Method: NIOSH
Express: No
Accreditation: Yes
Instruction: Se instruks for prøvetaking av luft med Radiello:
INSTRUKS
Remarks: Price for sampler Radiello in addition to the price of the analysis.
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: Report limit:
PCB 28 34 ng total
PCB 52 34 ng total
PCB 101 34 ng total
PCB 118 34 ng total
PCB 138 34 ng total
PCB 153 34 ng total
PCB 180 34 ng total

PCB-7 in air in adsorption tubes [Menu C1]

Package info

Price: 5.420 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 tube XAD-2 + 1 filter
Method: EN 1948-4
Express: No
Accreditation: Yes
Remarks: Measurement uncertainty 16%
See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: Report limit:
naphthalene 0.01 µg total
acenaphthylene 0.01 µg total
acenaphthene 0.01 µg total
fluorene 0.01 µg total
phenanthrene 0.01 µg total
anthracene 0.01 µg total
fluoranthene 0.01 µg total
pyrene 0.01 µg total
benzo(a)anthracene 0.01 µg total
chrysene 0.01 µg total
benzo(b)fluoranthene 0.01 µg total
benzo(k)fluoranthene 0.01 µg total
benzo(a)pyrene 0.01 µg total
dibenzo(ah)anthracene 0.01 µg total
benzo(ghi)perylene 0.01 µg total
indeno(1,2,3-cd)pyrene 0.01 µg total
sum of PAH-16 µg

PAH-16 in air in adsorption tubes [Menu C2]

Package info

Price: 2.330 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 tube XAD-2
Method: NIOSH 5515
Express: No
Accreditation: Yes
Remarks: See instructions for sampling with XAD-2 tubes in air:
INSTRUCTIONS
See instructions for sampling with PAH in air XAD-2-tube/ charcoal tube, filter:
INSTRUCTIONS
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: GBA
Analysis of substance: Report limit:
bisphenol A 1 µg total

Bisphenol-A in air

Package info

Price: 2.580 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Method: intern metode, GC-MS
Express: No
Accreditation: Yes
Remarks: See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: GBA
Analysis of substance: Report limit:
dimethyl phthalat 0.2 µg/sample
dietyl phthalate 0.2 µg/sample
di-n-propyl phthalate 0.2 µg/sample
di-n-butyl phthalate (DBP) 0.2 µg/sample
di-isobutyl phthalate 0.2 µg/sample
di-pentyl phthalate (DPP) 0.2 µg/sample
di-n-octyl phthalate 0.2 µg/sample
di-(2-ethylhexyl)phthalate (DEHP) 0.2 µg/sample
butylbenzylphthalate 0.2 µg/sample
di-cyclohexylphthalate 0.2 µg/sample
di-isodecyl phthalate (DIDP) 2 µg/sample
di-isononyl phthalate (DINP) 2 µg/sample

Phthalates in air

Package info

Price: 3.405 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Sample amount: 1 tube OVS-Tenax
Method: in-house method, GC-MSD
Accreditation: No
Remarks: See instructions for sampling with OVS tubes for PCBs in air:
INSTRUCTIONS
See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: GBA
Analysis of substance: Report limit:
Air volume L
fraction >C6-C7 1 mg/m3
fraction >C7-C8 1 mg/m3
fraction >C8-C9 1 mg/m3
fraction >C9-C10 1 mg/m3
fraction >C10-C11 1 mg/m3
fraction >C11-C12 1 mg/m3
fraction >C12-C13 1 mg/m3
n-hexane 0.2 mg/m3
n-heptane 0.1 mg/m3
n-octane 0.1 mg/m3
n-nonane 0.1 mg/m3
n-decane 0.1 mg/m3
n-undecane 0.1 mg/m3
n-dodecane 0.1 mg/m3
n-tridecane 0.1 mg/m3
n-tetradecane 0.1 mg/m3
n-hexadecane 0.1 mg/m3
dichloromethane 0.1 mg/m3
trichloromethane 0.1 mg/m3
tetrachloromethane 0.1 mg/m3
1,1-dichloroethane 0.1 mg/m3
1,2-dichloroethane 0.1 mg/m3
1,1,1-trichloroethane 0.1 mg/m3
1,1,2-trichloroethane 0.1 mg/m3
1,1,1,2-tetrachloroethane 0.1 mg/m3
1,1,2,2-tetrachloroethane 0.1 mg/m3
1,2-dichloropropane 0.1 mg/m3
1,3-dichloropropane 0.1 mg/m3
2,2-dichloropropane 0.1 mg/m3
cis-1,2-dichloroethene 0.1 mg/m3
trans-1,2-dichloroethene 0.1 mg/m3
trichloroethene 0.1 mg/m3
tetrachloroethene 0.1 mg/m3
1,1-dichloro-1-propene 0.1 mg/m3
cis-1,3-dichloro-1-propene 0.1 mg/m3
trans-1,3-dichloro-1-propene 0.1 mg/m3
1,2,3-trichloropropane 0.1 mg/m3
hexachlorobutadiene (HCB) 0.1 mg/m3
2-methylhexane 0.1 mg/m3
4-phenylcyclohexene 0.1 mg/m3
cyclohexane 0.1 mg/m3
isooctane 0.1 mg/m3
methylcyclohexane 0.1 mg/m3
methylcyclopentane 0.1 mg/m3
Sum of individual determined VOCs (M4) mg/m3

TVOC in air by GC-MS - group A - calc. (mg/m3)

Package info

Price: 1.560 NOK / sample
Std. response time: 10 work days
Discount group: 5
Sample type: Air/Work environment
Analysis type: Organic compounds
Method: In-house method, charcoal tube
Express: No
Accreditation: Yes
Remarks: See instructions for sampling with a low-flow adapter:
INSTRUCTIONS
Lab: ALS CZ
Analysis of substance: Report limit:
actinolite 1 påvist/ikke påvist
amosite 1 påvist/ikke påvist
anthophyllite 1 påvist/ikke påvist
chrysotile 1 påvist/ikke påvist
crocidolite 1 påvist/ikke påvist
tremolite 1 påvist/ikke påvist

Asbestos, qualitative, in material [A-1b]

Package info

Price: 1.030 NOK / sample
Std. response time: 5 work days
Fastest response time: Sameday
Discount group: 1
Sample type: Construction material etc.
Analysis type: Particles/asbestos
Sample amount: 2cm^3, more if the sample material is inhomogenous
Container: Double Ziplock bag
Method: SEM (ISO 22262-1:2012)
Express: Yes, Fastest delivery sameday ekspress: 300% addition, 09.00: 200%, 1d: 100%, 2d: 75%, 3d: 50%, 4d: 30%, 5d: 20%
Accreditation: Yes
Remarks: Limit for detected/not detected
Lab: ALS Oslo

1 Detection limit is 0,1 weight%